Carport tensioned membrane structure need to be aware of the fire protection problems

Share:
Hits: 2370 Publication time: 2018-12-05 SML

Often smoke fire in the event of a strong, strong thermal radiation and the fire extending speed very fast, it not for the membrane structure of the new project we also lack of actual combat experience, for this kind of building fire and its high span large space for the ascent of firefighters, fire water supply and internal work on probing is to bring a lot of suffering. So we need to pay attention to in the usual membrane structure carport fire problem.





Firstly, due to the membrane structure engineering of space span is very big, it is difficult to distinguish between initial fire partition, it is easy to occur when the fire fire phenomenon. Membrane structure have mostly been used Eng architectural exhibition hall and exhibition hall, gymnasium, theatre and the audience, its length, area could be determined according to the need, but if it is used in the market, school, dining hall and other buildings, to distinguish the fire zone was very difficult, but then we all have to suffering fire zone, or in the event of fire, all kinds of vertical channels have played an important role in drawing fire tube, and when the lower flue gas at the membrane surface at the top of the air movement can let a fire spreading horizontally, the fire will be more expand.


Secondly, the construction personnel at the time of erection of membrane structure engineering difficulties.


Membrane structure because of its large span space, construction personnel arrived in outdoor export the ear in membrane space distance is long, so the time is long. Spread smoke up to the level and direction at the same time, blocked the construction personnel in the horizon, increased the difficulty of distractions.


Thirdly, the automatic fire fighting equipment for fire detection is not timely, its role is very difficult to make up the fire.


In general membrane structure engineering of internal space is very high, fire, smoke at the time of extension, automatic detector of action than in the general's action to slow some of the buildings, and we usually use automatic water spray fire fighting devices is difficult to install in the membrane structure engineering, for on-site fire fighting and make up for the membrane structure engineering of the large space fire loss is very difficult.


Above is what we need to pay attention to in daily life of membrane structure sheds the fire problem. Although we all know that membrane structure material itself has the flame retardancy, but different material fireproof rank is also different, according to "code for fire protection design" and "code for fire protection design of tall buildings" mentioned in the class, PTFE membrane material can achieve A level, and on the basis of the nylon fabric coated PVC membrane materials can only achieve B1.





Key words:
Relevant information

Service Hotline0755 27809070

Shenzhen: 2nd floor Huizhou, Baoan Xixiang Baoyunda Logistics Research and Development Center, Shenzhen: 8th floor, Block B, Jinhaoyuan Building, Huiyang District, Huizhou City, Guangdong Province
Email: folan@sz1680.com
Copyright 2018 Shenzhen Folan Space Membrane Structure Co., Ltd. all rights reserved.
Guangdong ICP prepare No. 18128411 -1
Technical support: 國人在線 Disclaimer Website map

WeChat 2D code

丰满熟女人妻少妇在线视频| 黄色av网站免费在线观看| 免费看国产曰批40分钟1 | 亚洲欧美日韩色| 国产福利精品一区| 日本japanese丰满白浆| 办公室揉弄高潮嗯啊视频| www.av免费观看| 久久福利av| 欧美性jizz性欧美36| 欧美丰满熟妇bbbbbb乱大片| 天堂中文在线资源| 熟女高潮av| 国产精产国品一二三产区| 天堂8在线天堂资源8使用方法 | 色婷婷综合久久精品一区二区三区| sm调教片视频在线观看| 国产成人精品白浆久久91第1集| 四虎影院永久免费观看| 搜救在线观看高清完整版国语免费| 黄金视频app免费大全| 天天操天天摸天天日| 浙江妇搡bbbb搡bbbb| 国产大片黄| 国产aⅴ一区二区三区| 国产又粗又猛又爽| av蜜臀在线| 五十路人妻熟女一区二区三区漫画| 91久久久色在线观看| 亚洲性久久久久久久久| 精品久久久久久国产| 日韩aaa毛片| 国产v欧美v亚洲v精品v| 久久蜜桃网| 日韩精品欧美一区二区| 阿凡达讲的是什么故事| 亚洲精品乱码一品二品三品欧美 | 久久av中文字幕| 日韩高清色| 亚洲熟女少妇一区二| 亚洲乱码国产乱码精品精不卡 |